Clinical evaluation of the Elecsys β-CrossLaps serum assay, a new assay for degradation products of type I collagen C-telopeptides

104Citations
Citations of this article
43Readers
Mendeley users who have this article in their library.

Abstract

Background: The Elecsys β-CrossLaps serum assay measures type I collagen degradation fragments (β-CTx) that contain the β-isomerized octapeptide EKAHD-β-GGR. We investigated the analytical performance of the assay and changes in β-CrossLaps in patients with metabolic bone diseases. Methods: The electrochemiluminescent sandwich immunoassay uses two monoclonal antibodies directed against different regions of the linear EKAHD-β-GGR. Results: β-CrossLaps (β-CTx) immunoreactivity was stable in serum and plasma stored at 4 °C for 24 h or at room temperature for 4 h, and it did not decrease appreciably in samples stored at -30 °C for 12 weeks. Nine cycles of repeated freezing-thawing did not affect serum β-CTx. The intra- and interassay imprecision (CVs) for four samples was ≤2.6% (n = 10) and ≤4.1% (n = 10), respectively. The mean day-to-day biological variation (CV) was 20% in 10 postmenopausal women (n = 10 days). Serum β-CTx and osteocalcin were correlated in patients with hyperparathyroidism (r = 0.796; P <0.0001; n = 28), chronic renal failure on hemodialysis (r = 0.784; P = 0.0003; n = 16), hypoparathyroidism (r = 0.950; P = 0.0001; n = 11), and pseudohypoparathyroidism (r = 0.987; P = 0.130; n = 4). Serum β-CTx decreased by 47.4% ± 8.8% (mean ± SD) and 60.7% ± 6.5% at 3 and 6 months, respectively, after initiation of estrogen replacement therapy in 34 women. These decreases were greater than the decreases in urinary excretion of deoxypyridinoline (31.8% ± 3.9% and 38.1% ± 4.4%, respectively) or pyridinoline cross-linked C-terminal telopeptide of type I collagen (15.9% ± 3.9% and 16.9% ± 4.6%, respectively). Conclusions: The Elecsys β-CrossLaps serum assay provides a potentially useful tool for assessing bone resorption state, including its response to estrogen replacement therapy. © 2001 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Okabe, R., Nakatsuka, K., Inaba, M., Miki, T., Naka, H., Masaki, H., … Nishizawa, Y. (2001). Clinical evaluation of the Elecsys β-CrossLaps serum assay, a new assay for degradation products of type I collagen C-telopeptides. Clinical Chemistry, 47(8), 1410–1414. https://doi.org/10.1093/clinchem/47.8.1410

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free