Abstract
We present a theoretical and experimental study in which we increased the sensitivity of a phase-sensitive optical time-domain reflectometer (phi-OTDR). This was achieved by constructing coils in the sensor cable, which increased the total amplitude of the impact on the fiber. We demonstrate this theoretically using the example of a phase-sensitive reflectometer model and practically in testing grounds with a buried nearby conventional sensor and a sensor with coils. The sensitivity increased 2.2 times. We detected 95% of events when using coils, versus 20% when using a straight cable. The suggested method does not require any modifications to the device.
Author supplied keywords
Cite
CITATION STYLE
Stepanov, K. V., Zhirnov, A. A., Koshelev, K. I., Chernutsky, A. O., Khan, R. I., & Pnev, A. B. (2021). Sensitivity improvement of phi-otdr by fiber cable coils. Sensors, 21(21). https://doi.org/10.3390/s21217077
Register to see more suggestions