Abstract
The reversible operation of the heat pump process and the organic Rankine cycle as a Carnot battery has gained attraction of the scientific community in recent years. Despite numerous publications investigating the potential of such systems as a new energy storage technology, experimental results are scarce. The present work presents the outcomes on process level of a first experimental characterization of a reversible heat pump – organic Rankine cycle (HP-ORC) pilot plant designed for a maximum charging capacity of 15 kWel in heat pump mode and discharging capacity of 9 kWel in ORC mode. The experimental campaign comprised 150 stationary operating points. The plant yielded a maximum COP of 9.5 and a maximum ORC net efficiency of 4.4% for the defined boundary conditions of this experimental campaign. While the heat pump favors low temperature lifts for a high COP, high temperature gradients are favorable for ORC operation. Moreover, limitations on component and system level were determined. The challenging aspect of a proper fluid management of such reversible systems was identified as a crucial factor. Finally, the impact of fluid charge on ORC operation was experimentally evaluated and revealed significant optimization potential by means of an adequate fluid management.
Cite
CITATION STYLE
Weitzer, M., Kolb, S., Müller, D., & Karl, J. (2024). REVERSIBLE HEAT PUMP-ORC PILOT PLANT – EXPERIMENTAL RESULTS AND FLUID CHARGE OPTIMIZATION. In International Seminar on ORC Power Systems (pp. 430–438). Knowledge Center on Organic Rankine Cycle Technology (KCORC). https://doi.org/10.12795/9788447227457_72